Product Name: |
100w HPS Electronic Ballast
|
Supply Ability: |
50000 |
Related proudcts |
hps ballast, 100w hps ballast, 100w ballast, |
Specifications |
size:157*100*43mm |
Price Term: |
EXW |
Port of loading: |
|
Minimum Order |
1 |
Unit Price: |
USD22.9 |
|
The size of this ballast also can be customized. Description Test Standard Input Voltage (V) 220 Power Factor ¡Ý0.95 Input Wattage (W)¡À3W¡¡ 112 Input Current (A) 0.51 T.H.D. (%) <10% Lamp Working Voltage (V)¡À3% 102 Lamp Working Current (A)¡À3% 1.0 Lamp Working Wattage (W)¡À3% 100 Lamp Working Frequency (HZ)¡À5% 130 A.C.F (Lamp current waveform) LF square wave HI-POT 1.5KV,3S Creepage ¡Ü1.5mA Noisc level db £¼35dB Test Equipment£º
1¡¢Electrical parameter tester : PF1211 2¡¢voltage regulator : C02 3¡¢Hi-pot Tester :CJ2672S 4¡¢HID Comprehensive performance tester :UI2000 5¡¢Tube : FSL¡ªMH-S 150W/4K
¶þ¡¢ Protection Function
1¡¢ Tube Open Circuit
When Output end open (ie.:the tube is too hot to ignite), the ballast will stop to output. After this, need to ignition 1 time every three minutes. If continuous ignition twenty times still cannot light will stop igniting.
2¡¢ Tube Shorten protection
When output end is shorten, the ballast will stop to ouput . The ballast will reignite until trouble removal.
3¡¢ Over Voltage Protection
1) When the input voltage is 176-264VAC, the ballast is working in normal situation.
2) When the input voltage is over 264VAC, the over voltage protection will open to protect the ballast immediately.
3) When it is 320VAC, the ballast can work in safe by over voltage protection for 48 hours( The ballast will still work by the voltage come down until it is back to normal voltage for 48hours.)
4) When it is 350VAC, the ballst can work in safe by over voltage protection for 2hours.(Do the same fuction as the 320VAC).
5) When it is 380VAC, it can work in safe by over voltage protection for 5mins.(Do the same function as the 320VAC).
6) When the voltage is over 380VAC, the ballast maybe destroyed.
7)When the input voltage is below 176VAC, the output voltage of the ballast will be down follow the voltage until extinguishing at the end.